Table 71: Special Instrucons to Follow Before Connecng Earth Ground to an EX Series Switch
Switch Special Instrucons
EX2300-C You must install the EX2300-C in a restricted-access locaon and ensure that the chassis is
always properly grounded. The EX2300-C has a two-hole protecve grounding terminal
provided on the chassis. Under all circumstances, use this grounding connecon to ground
the chassis. For AC-powered systems, you must also use the grounding wire in the AC
power cord along with the two-hole grounding lug connecon. This tested system meets or
exceeds all applicable EMC regulatory requirements with the two-hole protecve
grounding terminal.
EX3200 and
EX4200
Some early variants of EX3200 and EX4200 switches for which the Juniper Networks
model number on the label next to the protecve earthing terminal is from 750-021
xxx
through 750-030
xxx
require 10-24x.25 in. screws.