Table 90: Chassis Component Alarm Condions on EX4300 Switches
(Connued)
Chassis Component Alarm Condion Alarm Severity Remedy
Management
Ethernet interface
Management
Ethernet link is
down
Major (red)
Check whether a cable is connected to the
management Ethernet interface, or whether
the cable is defecve. Replace the cable if
required.
If you are unable to resolve the problem,
open a support case using the Case
Manager link at hps://www.juniper.net/
support/ or call 1-888-314-5822 (toll-free
within the United States and Canada) or
1-408-745-9500 (from outside the United
States).
Roung Engine /var paron usage
is high.
Minor (yellow
or amber)
Clean up the system le storage space on the
switch. For more informaon, see Freeing Up
System Storage Space.
/var paron is full. Major (red) Clean up the system le storage space on the
switch. For more informaon, see Freeing Up
System Storage Space.
Rescue conguraon
is not set.
Minor (yellow
or amber)
Use the request system configuration rescue
save command to set the rescue conguraon.
Feature usage
requires a license or
the license for the
feature usage has
expired.
Minor (yellow
or amber)
Install the required license for the feature
specied in the alarm. For more informaon,
see Understanding Soware Licenses for EX
Series Switches.
SEE ALSO
Field-Replaceable Units in EX4300 Switches | 52
Chassis Status LEDs on EX4300 Switches | 69
Understand Alarm Types and Severity Levels on EX Series Switches | 320