Table 90: Chassis Component Alarm Condions on EX4300 Switches
(Connued)
Chassis Component Alarm Condion Alarm Severity Remedy
Management
Ethernet interface
Management
Ethernet link is
down
Major (red)
• Check whether a cable is connected to the
management Ethernet interface, or whether
the cable is defecve. Replace the cable if
required.
• If you are unable to resolve the problem,
open a support case using the Case
Manager link at hps://www.juniper.net/
support/ or call 1-888-314-5822 (toll-free
within the United States and Canada) or
1-408-745-9500 (from outside the United
States).
Roung Engine /var paron usage
is high.
Minor (yellow
or amber)
Clean up the system le storage space on the
switch. For more informaon, see Freeing Up
System Storage Space.
/var paron is full. Major (red) Clean up the system le storage space on the
switch. For more informaon, see Freeing Up
System Storage Space.
Rescue conguraon
is not set.
Minor (yellow
or amber)
Use the request system configuration rescue
save command to set the rescue conguraon.
Feature usage
requires a license or
the license for the
feature usage has
expired.
Minor (yellow
or amber)
Install the required license for the feature
specied in the alarm. For more informaon,
see Understanding Soware Licenses for EX
Series Switches.
SEE ALSO
Field-Replaceable Units in EX4300 Switches | 52
Chassis Status LEDs on EX4300 Switches | 69
Understand Alarm Types and Severity Levels on EX Series Switches | 320