1. Unlock and open the door(s) of
the charging power unit.
In each cabinet, set the
miniature circuit breaker (MCB)
for control voltage (2) and main
switch (1) to OFF position.
Disconnect the AC power supply
to the unit from the main supply
point (3).
Complete the lockout-tagout
(LOTO) procedure.
WARNING
After you disconnect the power supply, wait a minimum of two minutes
for the capacitors of the power modules to discharge before you continue.
Before you start work, measure the voltage of the electrical circuits to
make sure that no dangerous voltage remains.
2. Remove the power module.
Set the power module's circuit
breakers in OFF position (down).
Remove the four T30 fixing
screws on the edges of the
module's front panel.
The module moves on its rollers
on the rack. Use the handles to
carefully pull out the module.
NOTICE
Protect the components that
are installed back into the unit
from dirt.