Loading...
10. Kempower Technical Support remotely enables the equipment stop
function. Give the serial number of your charging unit in the support
request.
CAUTION
The system must be rebooted to complete the software configuration.
Stop any ongoing charging session before you continue. You can disable
charging units from ChargEye. Kempower recommends that you also
visibly notify users that the charging unit is not in use.
11. Do a functional test:
Start charging a suitable electric vehicle or an EV simulator/
charger tester for a minimum of 1 minute per vehicle
connector.
During charging, push the equipment stop button. Make sure
that each charging unit in the system goes into service mode.
Release the equipment stop button.
Reboot the system to reset it.
12.
Complete the Kempower field visit report. Submit the completed
document to ChargEye. For additional information, contact
Kempower Technical Support.
CHARGING EQUIPMENT FOR ELECTRIC VEHICLES INSTALLATION MANUAL
CONFIDENTIAL – CERTIFIED PARTNERS 113 REV 2.40 EN 04-2024