6. First install the cable bushing
and then the hose clamp on the
charging cable.
7. Route the charging cable inside
the unit through the rubber
grommet. Make sure that the
part of the charging cable inside
the unit has:
Approximately 50 mm of
insulation
Approximately 350–550
mm of stripped wire
8. Make sure that the wires reach
the terminals.
9. Make sure that the rubber
grommet's seal sets correctly on
the charging cable:
Push the charging cable
slightly inside the unit so
that the seal goes inside the
unit.
Tighten the seal in place
with the hose clamp.