About the KVAL Calibration Routine
3-5
KVAL 994-X Operation/Service Manual
Calibration Slot Drilling Specifications
The calibration routine will route a slot with known dimensions as a reference. The placement of
the slot and the parameters of the cut can help in dialing in the calibration. Each tool in the Car-
riage Head will be part of the slot drilling process. For the steps to machine the slot, see “Run the
Calibration Routine” on page 3-6.
The Calibration slot dimensions and position will vary with the diameter of the drills and the
door width.For information on making adjustments, see “Check Specifications of the Front Sec-
tion” on page 3-7.
TABLE 3- 2. Cal Slot Dimensions
Assembly Length Width Depth Vertical Position Position
Standard
Router
2.00 ''+ Diameter of Drill Diameter of Router 0.050 '' Center of Door Edge Center of H- Block
C-Rotate
Router
2.00 ''+ Diameter of Drill Diameter of Router 0.100 '' Center of Door Edge Center of H-Block
Drill N/A Diameter of Drill 0.250 '' Center of Slot Center of slot
Drill
Standard Router
Counter Rotate Router
H-Block Width 5-1/2””
Using the table above for ref-
erence dimensions, measure:
a.The Center of the Drill
hole
b.The centering of the
Standard Router Cut
c.The centering of the
Counter Rotate Router
Cut.
d.The Depths of all cuts
a
a
b
b
c
c