Group 8 Job Editor Page 127
JET3 Series Release 2.02
Automatic change is switched off
Automatic change is switched on
1 Dialog box <Basic Settings>
3 Check box <Summer-/Wintertime>
2 Tab <Date/Time>
7.3.1.3 Interval operation - Set interval time
The mode <Interval operation> enables the input of start- and end times when the printer
turns on or off automatically (e.g. 10.20 pm, the device turns on / 10.40 pm, the device
turns off) to circulate the ink.
The printer provides three free configurable time frames for interval operation. It is not
mandatory to use all three time frames.
This function prevents that the ink dries up or sediments as well as the jamming of the
nozzle if the printer is turned off for a longer time.
As standard the interval operation is carried out without viscosity control. In case of need
the viscosity control can be also activated for the interval operation.
ATTENTION
The viscosity control should be only activated for special operating
conditions of the printer or after consultation with the LEIBINGER-service
department.
You should set an interval time of at least 20 minutes.