Group 5 Transport/Start up Page 57
JET3 Series Release 2.02
5.5.3.2 Mechanical installation
ATTENTION
For the mechanical installation of the shaft encoder you have to pay
attention in any case that the encoder is protected against axial and radial
strain during the mounting and the continuous operation. For this a rubber
gaiter or a plastic coupling is used.
If the conditions allow it, the shaft encoder can be also adapted to a production line with a
friction wheel.
ATTENTION
Risk of injury!
The shaft encoder has to be installed or mounted that no risks of injury
can occur!
5.5.4 Interface X4 - Digital inputs
19 inputs for special functions are available whereof the connections of 6 inputs can be
freely selected.
Plug assignment:
Pin connection:
Pin
Designation
Pin
Designation
1
+Reset Counter
14
+24V
(1)
2
+Increment Counter
15
GND Reset Counter /
Increment Counter
3
+Jobselect 0
16
+Jobselect 1
4
+Jobselect 2
17
+Jobselect 3
5
+Jobselect 4
18
+Jobselect 5
6
+Jobselect 6
19
+Jobselect 7
7
+Jobselect 8
20
+Jobselect 9
8
GND Jobselect 0-9
21
GND Input 0-5
9
+Input 0
22
+Input 1
10
+Input 2
23
+Input 3
11
+Input 4
24
+Input 5
12
+Power ON
25
GND Power On
13
GND 24V

Table of Contents