Page 56 Transport/Start up Group 5
Release 2.02 JET3 Series
5.5.3 Interface X1 - Encoder
5.5.3.1 Description and configuration
The interface X1 provides the connection of a shaft encoder.
Due to the input for which you can set the software individually, the encoders can be
connected according to different norms without an additional converter.
Note: For variable product speed you have to use a shaft encoder to synchronize the
printing speed or to control the constant font width.
Basic data /Recommended working conditions:
Difference input +/-200mV
Input voltage range: -0,3 bis 5,5V
The signal type which should be used as encoder source has to be set in
the software of the printer under Settings Basic Settings Encoder
Interface.
You will find a circuit diagram of the interface in the manual appendix!
(1)
All 24V power supply outputs on X1, X3, X4 and X5 are distributed over a common resettable fuse
with 700mA max. current.
Please ensure that the sum of current are not exceed 700 mA.