Page 150 Job Editor Group 8
Release 2.02 JET3 Series
7.3.3.2 Digital Outputs
With the tab <Outputs> you can assign printer states and messages to the available
outputs.
ATTENTION
Standardly the outputs 1-3 are already predefined!
Output 1 (X3.1) = Error
Output 2 (X3.2) = Warning
Output 3 (X3.3) = Printer busy
E.g.: The output X3.9 (Pin No. 9 of interface X3) should be assigned to the message
“Product counter reached value”.
Proceeding:
Press on the tab <Outputs> (2) to select the tab.
Press on the arrow key of the drop-down list of the output [X3.9] (3). The drop-
down list provides a list of events/signals for selection.
Now select the required event/signal.
INFORMATION
Please see chapter 5.5.5 Interface X3 - Digital outputs for details about
digital outputs
Figure
63
Assign states and messages to digital outputs
1 – Dialog box <I/O Settings>
3 – Drop-down list <X3.9>
2 – Tab <Outputs>
4 – Pin designation
2
4
3
1