Page 50 Transport/Start up Group 5
Release 2.02 JET3 Series
Turn on the printer. For this touch the dark touch-display (1) at any position for
approx. 2 sec.
The device turns on and the main window with the message<Initialization> (2) is
displayed. Wait until the initialization is finished. After this process the
message<Emergency Shutdown> (3) is displayed.
Press the button <OK> (4).
Change to tab <Special functions /Tools> (5).
Now press the button <Fill up Routine> (6). The message <Fill up Routine> (7) is
faded-in.
Press the button <Next> (8) to start the filling routine.
Note:
This process takes approx. 10 minutes.
After finishing the process an according message (9) is displayed. Press the button
<OK> (10) to finish the routine.
Press the button <Close> (11) to leave the menu <Special functions /Tools>.
The message <Hydraulic control> (12) is faded-in.
Note:
For leaving the service menu the hydraulic control will be turned on again
automatically.
Press the button <OK> (13) to close the service menu.
The main window (14) is now displayed. If required the device starts automatically
with the bleeding of the system.
During the process the message <Bleeding> (4) is displayed. The bleeding takes
between 1 5 min. The process can be canceled by pressing the button <Cancel>
(5).
Now the printer is ready to operate.