Address Designaon Default seng Data type Factor A M
0x29E0:002 Field weakening controller sengs: Reset me
(ASM)
2000.0 ms U32 10 -
0x29E1 Field weakening controller Field limitaon 100.00 % U16 100 - ●
0x29E2 DC-bus lter me 25.0 ms U16 10 -
0x29E3 Motor voltage lter
me 25.0 ms U16 10 -
0x29E4 Voltage reserve range 5 % U8 1 -
0x2B00 V/f characterisc shape Linear [0] U8 C
0x2B01:001 V/f shape data: Base voltage 225 V U16 1 -
0x2B01:002 V/f shape data: Base frequency 270 Hz U16 1 -
0x2B02:001 Frequency grid points (x) user V/f characterisc: x1
= f01
-50 Hz I16 1 -
0x2B02:002 Frequency grid points (x) user V/f characterisc: x2
= f02
-40 Hz I16 1 -
0x2B02:003 Frequency grid points (x) user V/f characterisc: x3
= f03
-30 Hz I16 1 -
0x2B02:004 Frequency grid points (x) user V/f characterisc: x4
= f04
-20 Hz I16 1 -
0x2B02:005 Frequency grid points (x) user V/f characterisc: x5
= f05
-10 Hz I16 1 -
0x2B02:006 Frequency grid points (x) user V/f characterisc: x6
= f06
0 Hz I16 1 -
0x2B02:007 Frequency grid points (x) user V/f characterisc: x7
= f07
10 Hz I16 1 -
0x2B02:008 Frequency grid points (x) user V/f characterisc: x8
= f08
20 Hz I16 1 -
0x2B02:009 Frequency grid points (x) user V/f characterisc: x9
= f09
30 Hz I16 1 -
0x2B02:010 Frequency grid points (x) user V/f characterisc: x10
= f10
40 Hz I16 1 -
0x2B02:011 Frequency grid points (x) user V/f characterisc: x11
= f11
50 Hz I16 1 -
0x2B03:001 Voltage grid points (y) user V/f characterisc: y1 =
U01 (x = f01)
400.00 V U32 100 -
0x2B03:002 Voltage grid points (y) user V/f characterisc: y2 =
U02 (x = f02)
320.00 V U32 100 -
0x2B03:003 Voltage grid points (y) user V/f characterisc: y3 =
U03 (x = f03)
240.00 V U32 100 -
0x2B03:004 Voltage grid points (y) user V/f characterisc: y4 =
U04 (x = f04)
160.00 V U32 100 -
0x2B03:005 Voltage grid points (y) user V/f characterisc: y5 =
U05 (x = f05)
80.00 V U32 100 -
0x2B03:006 Voltage grid points (y) user V/f characterisc: y6 =
U06 (x = f06)
0.00 V U32 100 -
0x2B03:007 Voltage grid points (y) user V/f characterisc: y7 =
U07 (x = f07)
80.00 V U32 100 -
0x2B03:008 Voltage grid points (y) user V/f characterisc: y8 =
U08 (x = f08)
160.00 V U32 100 -
0x2B03:009 Voltage grid points (y) user V/f characterisc: y9 =
U09 (x = f09)
240.00 V U32 100 -
0x2B03:010 Voltage grid points (y) user V/f characterisc: y10 =
U10 (x = f10)
320.00 V U32 100 -
0x2B03:011 Voltage grid points (y) user V/f characterisc: y11 =
U11 (x = f11)
400.00 V U32 100 -
0x2B04 V/f boost controller - current setpoint 0.00 A U32 100 -
0x2B05:001 V/f boost controller sengs: Gain 148.21 V/A U32 100 -
0x2B05:002 V/f boost controller sengs: Reset me 3.77 ms U32 100 -
0x2B06 Voltage boost 0.0 V U16 10 -
0x2B07:001 Load adapon: Direcon of rotaon Passive load [0] U8 C
* Default seng depending on the size.
Appendix
P
arameter aribute list
474