Address Designaon Default seng Data type Factor A M
0x2D4D:006 Motor ulisaon (i²xt) - specic
characterisc: y3 =
i03/iN (x3)
100 % U16 1 -
0x2D4D:007 Motor ulisaon (i²xt) - specic characterisc: x4 =
n04/nN (n04 = limit eld weakening)
100 % U16 1 -
0x2D4D:008 Motor ulisaon (i²xt) - specic characterisc: y4 =
i04/iN (x4)
100 % U16 1 -
0x2D4E Motor ulisaon (i²xt) - warning threshold 100 % U16 1 -
0x2D4F Motor ulisaon (i²*t) x % (Read only) U16 1 X
0x2D50:001 Motor ulisaon (i²xt) - monitoring: Error response Fehler > CiA402 [1] U8 -
0x2D50:002 Motor ulisaon (i²xt) - monitoring: Error threshold 105 % U16 1 -
0x2D51:001 Posion error/speed error - monitoring: Speed error
- error threshold
50 rpm U32 1 -
0x2D51:002 Posion error/speed error - monitoring: Speed error
- min. me for error
0 ms U16 1 -
0x2D51:003 Posion error/speed error - monitoring: Speed error
- error response
No response [0] U8 -
0x2D51:004 Posion error/speed error - monitoring: Posion
error - error threshold
360 ° U32 1 -
0x2D51:005 Posion error/speed error - monitoring: Posion
error - min. me for error
0 ms U16 1 -
0x2D51:006 Posion error/speed error - monitoring: Posion
error - error response
No response [0] U8 -
0x2D66:001 Mains failure control: Enable funcon Disabled [0] U8 -
0x2D66:002 Mains failure control: DC-bus acvaon level 75 % U8 1 -
0x2D66:011 Mains failure control: Filter me 0.00 s U16 100 -
0x2D66:012 Mains failure control: Ramp max. torque 30.0 % U16 10 -
0x2D66:013 Mains failure control: Ramp me 1.00 s U16 100 -
0x2D66:014 Mains failure control: Actual DC-bus voltage x.xxx V (Read only) U32 1000 X
0x2D81:001 Life-diagnosis: Operang
me x s (Read only) U32 1 X
0x2D81:002 Life-diagnosis: Power-on me x s (Read only) U32 1 X
0x2D81:004 Life-diagnosis: Main switching cycles - (Read only) U32 1 X
0x2D81:006 Life-diagnosis: Short-circuit counter - (Read only) U32 1 X
0x2D81:007 Life-diagnosis: Earth fault counter - (Read only) U32 1 X
0x2D81:009 Life-diagnosis: Fan operang
me x s (Read only) U32 1 X
0x2D82 Motor actual voltage (Ve) x.x V (Read only) U32 10 X
0x2D83:001 Motor-Phasenströme: Zero system current x.xx A (Read only) I32 100 X
0x2D83:002 Motor-Phasenströme: Phase U current x.xx A (Read only) I32 100 X
0x2D83:003 Motor-Phasenströme: Phase V current x.xx A (Read only) I32 100 X
0x2D83:004 Motor-Phasenströme: Phase W current x.xx A (Read only) I32 100 X
0x2D84:001,
004, 006
Heatsink temperature: Heatsink temperature x.x °C (Read only) I16 10 X
0x2D84:002 Heatsink temperature: Heatsink temperature: Warn-
ing thr
eshold
90.0 °C I16 10 -
0x2D8A Actual speed error x rpm (Read only) I32 1 X
0x2DA2:001 Output power: Eecve power x.xxx kW (Read only) I32 1000 X
0x2DA3:003 Output energy: Warning 0.00 kWh I32 100 X
0x2DA4:001 Diagnoscs of analog input 1: Value in percent x.x % (Read only) I16 10 X
0x2DA4:005 Diagnoscs of analog input 1: Scaled percent value x.xx % (Read only) I16 100 X
0x2DA4:016 Diagnoscs of analog input 1: Status - (Read only) U16 HX
0x2DD0:001 Field values: Actual value x % (Read only) U16 1 X
0x2DD0:002 Field values: Setpoint value x % (Read only) U16 1 X
0x2DD1:001 Motor currents: Actual D-current (id) x.xx A (Read only) I32 100 X
0x2DD1:002 Motor currents: Actual Q-current (iq) x.xx A (Read only) I32 100 X
0x2DD1:003 Motor currents: Setpoint D-current (id) x.xx A (Read only) I32 100 X
0x2DD1:004 Motor currents: Setpoint Q-current (iq) x.xx A (Read only) I32 100 X
0x2DD1:005 Motor currents: Motor current (Ie) x.xx A (Read only) I32 100 X
* Default seng depending on the size.
Appendix
P
arameter aribute list
482