EDS94ARNExxxx EN 2.3 - 06/2014 L 163
9400 regenerative power supply module | Parameter setting
"CAN on board" system bus
Implemented CANopen objects
I-1403
Communication parameter for the reception of process data via RPDO4
For the assignment of the data telegram see object I-1400
.
I-1600
The object I-1600 serves to receive parameter data via the RPDO1.
[6-16] Assignment of the data telegram
IEC 61131 process data words are mapped. Only whole bytes can be mapped (the mapping
entry granularity is 1 byte).
Index:
I-1403
Name:
RPDO4 communication parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Highest subindex supported 5 - (read access only) ro U8
1: COB-ID used by RPDO 0x500 + node ID 0 4294967295 rw U32
2: Transmission type 254 0 255 rw U8
3: Inhibit time - - (not used for RPDOs) rw U16
4: Compatibility entry - - (reserved, read or write access results in the error
message 0x06090011)
rw U8
5: Event timer - - (not used for RPDOs) rw U16
Subindex Meaning Lenze code
1 Identifier RPDO4
• The basic setting corresponds to the "Predefined
Connection Set": identifier = 0x500 + node ID
C00321/4
2 RPDO transmission type according to DS301 V4.02
Transmission type
( 113)
C00323/4
Index:
I-1600
Name:
RPDO1 mapping parameter
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Number of mapped application
objects in PDO
00 8rwU8
1 ... 8: Application object 1 ... 8 0 0 4294967295 rw U32
Subindex Meaning
0 Number of mapped objects
1 ... 8 Mapping entries 1 ... 8 for RPDO1
8th byte 7th byte 6th byte 5th byte
Data 4 Data 3 Data 2 Data 1
Bit31...bit16 Bit15...bit8
Bit 7 ... bit 0
Index Subindex Length