Weather station
This setting lets you view the temperature of the weather station sensor.
1 Enter the Diagnostics menu, and then touch Printer diagnostics & adjustments.
2 From the Weather station section, touch Start.
Fuser temperature
This setting lets you view the fuser temperature.
1 Enter the Diagnostics menu, and then touch Printer diagnostics & adjustments.
2 From the Fuser temperature section, touch Start.
Scanner Diagnostics
Feed Test
This test allows for a continuous feed from the ADF or
flatbed.
1 Enter the Diagnostics menu, and then navigate to:
Scanner diagnostics > Feed Test
2 Select a paper size.
3 From the Feed Test section, touch Start.
Sensor tests
This test
verifies
the status of the scanner sensors.
1 Enter the Diagnostics menu, and then touch Scanner diagnostics.
2 From the Sensor tests section, touch Start.
A dialog listing the sensor tests appears.
3 Find, and then manually toggle the sensor.
Notes:
• The sensor status on the screen toggles between 1 and 0 when the sensor is properly working.
• If a sensor test fails, the test failure may not indicate a failed sensor. Further troubleshooting may be
required. Check the boards and cables for possible issues.
7528
Service menus
286