EasyManua.ls Logo

Lexmark XC4150 - Additional Input Tray Diagnostics

Lexmark XC4150
575 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
To verify the result, do the following:
1 Load the ADF with a document containing light and dark content.
2 Print a two-sided copy of the document.
Notes:
If the back side of the copy has vertical streaks, then clean the scanner glass and backing material,
and then print another copy.
If the streaks still appear, then repeat the cleaning and verification procedure or replace the ADF.
Additional input tray diagnostics
Sensor tests
1 Enter the Diagnostics menu, and then touch Additional input tray diagnostics.
2 From the Sensor tests section, touch Start.
A dialog listing the sensor tests appears.
3 Find, and then manually toggle the sensor.
Notes:
The sensor status on the screen toggles between 1 and 0 when the sensor is properly working.
If a sensor test fails, the test failure may not indicate a failed sensor. Further troubleshooting may be
required. Check the boards and cables for possible issues.
Motor tests
1 Enter the Diagnostics menu, and then navigate to:
Additional input tray diagnostics > Motor tests
2 Select a motor, and then touch Start.
Notes:
If the motor is activated, then it is properly working.
Some motors require automatic deactivation in order to avoid secondary issues such as possible
damage and contamination.
Some tests require a special action to activate a motor such as removing a major component.
If the motor fails, the test failure may not indicate a failed motor. Further troubleshooting may be
required. Check the boards and cables for possible issues.