6 Insert a folded sheet of paper as shown to toggle the sensor (ADF input 1st scan).
Motor tests
1 Enter the Diagnostics menu, and then select navigate to:
Scanner diagnostics > Motor tests
2 Select a motor, and then touch Start.
Notes:
• If the motor is activated, then it is properly working.
• Some motors require automatic deactivation in order to avoid secondary issues such as possible
damage and contamination.
• Some tests require a special action to activate a motor such as removing a major component.
• If the motor fails, the test failure may not indicate a failed motor. Further troubleshooting may be
required. Check the boards and cables for possible issues.
Multifeed Calibration
1 Enter the Diagnostics menu, and then touch Scanner diagnostics.
2 Select Multifeed Calibration, and then touch Start.
Scanner Calibration Reset
Before starting the test, make sure that the scanner glass and backing material are clean.
1 Enter the Diagnostics menu, and then touch Scanner diagnostics.
2 From the Sensor Calibration Test section, touch Start.
7528
Service menus
289