Chapter 8 Table of Functions
G
8-6
No. Comm.No. Function Display Name Setting Range
Initial
Value
Shift in
Operatio
n
Control Mode
V/F
SL
VC
SLT
VCT
76 0h124C Acc Time-4 Acc/Dec Time 4 0~600[sec] 50.0 O
X X
77 0h124D Dec Time-4 Acc/Dec Time 4 0~600[sec] 50.0 O
X X
78 0h124E Acc Time-5 Acc/Dec Time 5 0~600[sec] 60.0 O
X X
79 0h124F Dec Time-5 Acc/Dec Time 5 0~600[sec] 60.0 O
X X
80 0h1250 Acc Time-6 Acc/Dec Time 6 0~600[sec] 70.0 O
X X
81 0h1251 Dec Time-6 Acc/Dec Time 6 0~600[sec] 70.0 O
X X
82 0h1252 Acc Time-7 Acc/Dec Time 7 0~600[sec] 80.0 O
X X
83 0h1253 Dec Time-7 Acc/Dec Time 7 0~600[sec] 80.0 O
X X
* The grey code refers to hidden code, emerging only in case of setting of the code.
Note 4)
BAS-24 is shown only when DRV-09 Control Mode is set as “Sensorless-2” or “Vector”.
Note 5)
BAS-41~48 is displayed only when it is set as “User V/F” even if there is only one BAS-07
or M2-V/F Patt (M2-25).
Note 6)
BAS-50~64 is displayed only when it is set as “sequential” (Speed –L.M.H,X) even if there
is only one multi-function input of IN-65-75.
Note 7)
BAS-72~75 is displayed only when it is set as “sequential Acc/Dec” (Xcel-L,M,H) even if
there is only one multi-function input of IN-72~75.
8.1.3 Parameter mode –Extended function group (PAR
Î
ADV)
No. Comm.No. Function Display Name Setting Range Initial Value
Shift in
Operation
Control Mode
V/
F
SL
VC
SLT
VCT
00
- Jump Code
j
ump code
0 ~ 9
9
24
O
O
O
O
O
O
01
0h1301
A
cc Pattern
acceleratin
g
pattern 0
Linea
r
0:Li-near
X
O
O
O
XX
0
2
0h1302 Dec Pattern
deceleratin
g
pattern 1
S-curve
X
O
O
O
XX
03
0h1303 Acc S Start
S accelerating starting
slope
1 ~ 100 [%] 40
X O O O X X
04
0h1304
A
cc S End
S acceleratin
g
end slope X
O
O
O
XX
05
0h1305 Dec S Start
S decelerating starting
slo
p
e
X O O O X X
06
0h1306 Dec S End
S deceleratin
g
end slo
p
eX
O
O
O
XX
07
0h1307 Start Mode
starting method
0
A
cc
0:
Acc
X O O O X X
1
Dc-Star
t
08
0h1308 Stop Mode
stop method
0
Dec
0: Dec
X O O O X X
1
Dc-Brake
2
Free-Run
3
Reserved
4
Powr Braking
09
0h1309 Run Prevent
rotation preventing
direction selection
0
None
0: None
X O O O X X
1
Forward Prev
2
Reverse Pre
v
10
0h130A Power-on Run
power input starting
0
N
o
0:No
O O O O X X
1
Ye
s

Table of Contents

Other manuals for LSIS SV-iS7 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS SV-iS7 series and is the answer not in the manual?

LSIS SV-iS7 series Specifications

General IconGeneral
BrandLSIS
ModelSV-iS7 series
CategoryInverter
LanguageEnglish

Related product manuals