Chapter 8 Table of Functions
G
8-30
8.1.9 Parameter mode – Auto sequence operation group (
AUT)
No. Comm. No.
Function
Display
Name Setting Range
Initial
Value
Shift in
Operation
Control Mode
V/
SL
VC
SLT
VC
00
-
Jump Code jump code
0
9
10
O
O
O
XX
01
0h1901
Auto Mode auto operation type
0
ut
-
0:
Auto-A
X
O
O
O
X X
1 Auto-B
0
Note30)
0h1902
Auto Check Auto operation terminal delay time
0.02 ~ 2.00 [s]
0.10 X
O
O
O
X X
03
0h1903
Seq Select sequence type selection
1 ~ 2
1 O
O
O
O
X X
04
Note31)
0h1904
Step
Number 1
Number of sequence 1 steps
1 ~ 8
2
O
O
O
O
X X
0
Note32)
0h1905
Step
Number 2
Number of sequence 2 steps O
O
O
O
X X
10
Note33)
0h190A
Seq 1/1
Freq
1/1 step frequency
0.01
~ maximum
frequency[Hz]
11.00 O
O
O
O
X X
11
0h190B
Seq 1/1
Xcel
1/1 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
12
0h190C
Seq 1/1
Stead
1/1 steady speed operation time O
O
O
O
X X
13
0h190D
Seq 1/1 Dir 1/1 operation direction
0 Reverse
1:
Forward
O
O
O
O
X X
1 Forward
14
0h190E
Seq 1/2
Freq
1/2 step frequency
0.01 ~ maximum
frequency[Hz]
21.00 O
O
O
O
X X
15
0h190F
Seq 1/2
Xcel
1/2 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
16
0h1910
Seq 1/2
Stead
1/2 steady speed operation time O
O
O
O
X X
17
0h1911
Seq 1/2 Dir 1/2 operation direction
0 Reverse
1:
Forward
O
O
O
O
X X
1 Forward
18
0h1912
Seq 1/3
Freq
1/3 step frequency
0.01 ~ maximum
frequency[Hz]
31.00 O
O
O
O
X X
19
0h1913
Seq 1/3
XcelT
1/3 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
20
0h1914
Seq 1/3
SteadT
1/3 steady speed operation time O
O
O
O
X X
21
0h1915
Seq 1/3 Dir 1/3 operation direction
0 Reverse
1:
Forward
O
O
O
O
X X
1 Forward
22
0h1916
Seq 1/4
Freq
1/4 step frequency
0.01 ~ maximum
frequency[Hz]
41.00 O
O
O
O
X X
23
0h1917
Seq 1/4
Xcel
1/4 Acc/Dec time
0.1 ~ 600.0 [s]
5.0 O
O
O
O
X X
24
0h1918
Seq 1/4
Stead
1/4 steady speed operation time
0.1 ~ 600.0 [s]
5.0 O
O
O
O
X X