Chapter 8 Table of Functions
G
8-27
8.1.8 Parameter mode – Applied function group (
APP)
No.
Comm.
No.
Function
Display
Name Setting Range
Initial
Value
Shift in
Opera-tion
Control Mod
V/F
S
VC
SLT
VCT
00 - Jump Code jump code
0
9
20
O
O
O
OO
01
0h1801
App Mode applied function selection
0 None
0:
None
X
O
O
O
XX
1 Traverse
2 Proc PID
3 Reserved
4
Auto Sequence
0
Note28)
0h1808
Trv Apmlit % traverse operating range
0 ~ 20 [%] 0.0
O
O
O
O
X X
0
0h180
Trv Scramb % traverse scramble magnitude
0
50 [%] 0.0
O
O
O
X X
10
0h180
Trv Acc Time traverse accelerating time
0.1 ~ 600.0 [s]
2.0
O
O
O
X X
11
0h180B
Trv Dec Time traverse decelerating time
3.0
O
O
O
X X
1
0h180
Trv Offset Hi traverse offset upper limi
0 ~ 20.0 [%]
0.0
O
O
O
X X
13
0h180D
Trv Offset l
traverse offset lower limi
0.0
O
O
O
X X
16
Note 29)
0h1810
PID Output PID output monitor
[%]
0.00
-
O
O
O
X X
17
0h1811
PID Ref Value PID reference monitor
50.00
-
O
O
O
X X
1
0h1812
PID Fdb Value PID feedback monitor
0.00
-
O
O
O
X X
1
0h1813
PID Ref Se
PID reference setting
-100
100 [%] 50%
O
O
O
X X
20
0h1814
PID
Ref Source
PID reference selection
0 Ke
ad
0: Key
pad
X
O
O
O
X X
1 V1
2 I1
3 V2
4 I2
5 Int 48
6 Encode
7 FieldBu
8 PL
9 S
nchr
10 Binar
T
e
* The grey code refers to hidden code, emerging only in case of setting of the code.
Note 28)
APP 08~13 codes are displayed only when APP-01 (App Mode) is set as “Traverse”.
Note 29)
APP 16~45 codes are displayed only when APP-01 (App Mode) is set as “Proc PID” or
APP-01(App Mode) is set as “MMC” and Requl Bypass(APO-34) is set as “No”.