Chapter 8 Table of Functions
G
8-36
8.1.11 Parameter mode – Protective function group (
PRT)
No. Comm. No.
Function
Display
Name Setting Range
Initial
Value
Shift in
Operat
-ion
Control Mode
V/F
SL
VC
SLT
VC
00 - Jump Code
ump code
0 ~ 9
40
04
0h1B04
Load Duty Load amount setting
0Normal Duty
1:Heavy
Duty
X O
OO O O
1Heavy Duty
05
0h1B05
Phase Loss Chk input/output phase open protection
Bit 00 ~ 11
00 X O O O O O
1 Output phase open
Input phase open
06
0h1B06
IPO V Band input phase open voltage band
1 ~ 100 [V]
40 X O O O O O
07
0h1B07
Trip Dec Time decelerating time in case of failure
0 ~ 600 [s]
3.0
08
0h1B08
RST Restart
starting selection in case of failure
reset
0N
0:No O O O O O O
1Ye
09
0h1B09
Retry Number Number of auto restarts
0 ~ 10
0O OOO OO
10
Note38)
0h1B0A
Retry Delay Auto restart delay time
0 ~ 60.0 [s]
1.0 O O O O O O
11
0h1B0B
Lost KPD Mode
movement in case of Keypad
command loss
0 None
0 : None O O O O O O
1Warning
2 Free-Run
3Dec
12
0h1B0C
Lost Cmd Mode
movement in case of speed
command loss
0 None
0 : None O O O O O O
1 Free-Run
2Dec
3 Hold Inpu
4 Hold Outpu
5 Lost Preset
13
Note39)
0h1B0D
Lost Cmd Time
Speed command loss judgment
time
0.1 ~ 120 [s] 1.0
O O O O O O
14
0h1B0E
Lost Preset F
operation frequency in case of
speed command loss
Start freq.
~ maximum frequency[Hz]
0.00 O O O O O O
15
0h1B0F
AI Lost Level
Analog input
loss judgment level
0 Half of x1
0: Half of
x1
O O O O O
1 Below x1
17
0h1B11
OL Warn Select overload alarm selection
0N
0 : No
OO O OO
1Ye
1
0h1B12
OL Warn Level overload alarm level
30 ~ 180 [%]
150
19
0h1B13
OL Warn Time overload alarm time
0 ~ 30.0 [s]
10.0
20
0h1B14
OL Trip Select
movement in case of overload
failure
0None
1 : Free-
Run
O O O O O O
1Free-Run
2Dec
21 0h1B15 OL Trip Level overload failure level 30 ~ 200 [%] 180
G
G
G