Chapter 8 Table of Functions
G
8-15
No. Comm. No.
Function
Display
Name Setting Range Initial Value
Shift in
Operation
1)Control Mod
V/F
SL
VC
SL
VC
70
0h1446 SS Mode
Speed search
mode selection
0 Flying Start-1
0
X
O
OO
XX
1 Flying Start-2
71
0h1447
Speed
Search
Speed search
operation selection
Bit 0000 ~ 1111
0000
X
O
OO
XX
1
accelerating speed
search selection
2
Reset start after trip
3
R
start after
instantaneous
interruption
4
Start immediately after
power ON
72
0h1448
SS Sup-
Current
speed search
standard current
80 ~ 200 [%]
Below
75kW
150
O
O
O
XXX
bove
90kW
100
73
0h1449 SS P-Gain
speed search
proportional gain
0 ~ 9999 100
O
O
O
XXX
74
0h144A SS I-Gain
speed search
integral calculus
gain
0 ~ 9999 200
O
O
O
XXX
75
0h144B
SS
Block Time
Pre-speed search
output
block time
0 ~ 60 [s] 1.0
X
O
O
XXX
77
0h144D KEB Select
energy buffering
selection
0N
0:No
X
O
OO
XX
1Ye
7
Note20)
0h144E
KEB Start
Le
energy buffering
start amoun
110 ~ 140 [%] 125.0
X
O
O O
X X
79
0h144F
KEB Stop
Le
energy buffering
stop amoun
125 ~ 145 [%] 130.0
X
O
O O
X X
82
Note21)
0h1452
ZSD
Frequency
permanent
detection
frequency
0 ~ 10 [Hz] 2.00
O X X
O
X
O
83
0h1453 ZSD Band
permanent
detection
frequency band
0 ~ 2 [Hz] 1.00
O X X
O
X
O
86
㨰
0h1456 KEB P Gain Energy Buffering P Gain 0~20000 1000 O O O O X X
87 0h1457 KEB I Gain Energy Buffering I Gain 1~20000 500 O O O O X X
88 0h1458 KEB Slip Gain
Energy Buffering Sli
Gain
0~2000.0[%] 30.0 O O O O X X
89 0h1459 KEB Acc Time
Energy Buffering Return
Acceleration Time