Chapter 8 Table of Functions
G
8-32
No. Comm. No.
Function
Display
Name Setting Range
Initial
Value
Shift in
Operation
Control Mode
V/
SL
VC
SLT
VC
47
0h192F
Seq 2/2
Freq
2/2 step frequency
0.01 ~ maximum
frequency[Hz]
22.00 O
O
O
O
X X
48
0h1930
Seq 2/2
XcelT
2/2 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
49
0h1931
Seq 2/2
SteadT
2/2 steady speed operation time O
O
O
O
X X
50
0h1932
Seq 2/2 Dir 2/2 operation direction
0 Reverse
1:
Forward
O
O
O
O
X X
1 Forward
51
0h1933
Seq 2/3
Freq
2/3 step frequency
0.01 ~ maximum
frequency[Hz]
32.00 O
O
O
O
X X
52
0h1934
Seq 2/3
Xcel
2/3 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
53
0h1935
Seq 2/3
Stead
2/3 steady speed operation time O
O
O
O
X X
54
0h1936
Seq 2/3 Dir 2/3 operation direction
0 Reverse
1:
Forward
O
O
O
O
X X
1 Forward
52
0h1937
Seq 2/4
Freq
2/4 step frequency
0.01 ~ maximum
frequency[Hz]
42.00 O
O
O
O
X X
56
0h1938
Seq 2/4
Xcel
2/4 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
57
0h1939
Seq 2/4
Stead
2/4 steady speed operation time O
O
O
O
X X
58
0h193A
Seq 2/4 Dir 2/4 operation direction
0 Reverse
1:
Forward
O
O
O
O
X X
1 Forward
59
0h193B
Seq 2/5
Freq
2/5 step frequency
0.01 ~ maximum
frequency[Hz]
52.00 O
O
O
O
X X
60
0h193C
Seq 2/5
Xcel
2/5 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
61
0h193D
Seq 2/5
Stead
2/5 steady speed operation time O
O
O
O
X X
62
0h193E
Seq 2/5 Dir 2/5 operation direction
0 Reverse
1:
Forward
O
O
O
O
X X
1 Forward
63
0h193F
Seq 2/6
Freq
2/6 step frequency
0.01 ~ maximum
frequency[Hz]
60.00 O
O
O
O
X X
64
0h1940
Seq 2/6
XcelT
2/6 Acc/Dec time
0.1 ~ 600.0 [s]
5.0
O
O
O
O
X X
65
0h1941
Seq 2/6
SteadT
2/6 steady speed operation time O
O
O
O
X X
66
0h1942
Seq 2/6 Dir 2/6 operation direction
0 Reverse
1:Forwar
d
O
O
O
O
X X
1 Forward
67
0h1943
Seq 2/7
Freq
2/7 step frequency
0.01 ~ maximum
frequency[Hz]
52.00 O
O
O
O
X X