NTP-004
: Acceptance 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
Determine the optical loss of the optical facility from office records
or by making the required measurements.
DLP-514
2.
NOTE:
The rtrv-map-network command may be used to
retrieve a map of the network, including the systems in the
network and how they are connected.
Ensure all DDM-2000 FiberReach shelves (
OLIUs
) in the network
have been properly connected to the optical facility. Verify the
integrity of each optical span.
3. Use rtrv-sync command at each DDM-2000 FiberReach node
to verify proper timing options. Each DDM-2000 FiberReach node
in the network should be set for
LineTimed
.
4.
!
CAUTION:
The
init-sys:all
command should NOT be used on an
in-service system.
NOTE:
During installation and/or initial testing, provisionable
parameters may have been set which need to be reset to
default values. VT1.5 (DS1) cross-connections may have
been made which should be deleted before the system is
placed in service. The init-sys:all command will reset
all provisionable parameters and cross-connections to
default values. Some parameters will have to be set again
later before service is established.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed, if the far-end
communications has not been enabled at both ends of the
system using the set-fecom: command.
If required, use the command init-sys:all to reset
provisionable parameters to default values.