363-206-305
Administration and Provisioning
8-68
Issue 3 June 2000
Provisioning channel units other than the
SPQ
494 channel unit in the NBS is done
the same way as provisioning channel units at the
SLC
-2000 RT/HDT. Once you
provision the shelves in the HDT for fiber distribution (via the
SLC
-2000 CIT or
UIP) and you set the number of lines hosted by each DT Server (via the CIT),
provisioning of individual channels in the ONU follows the service order flows
described for the RT/HDT.
NOTE:
See 363-208-001,
SLC-2000 Access System User/Service Manual,
and
363-205-004,
SLC-2000 MSDT User/Service and Ordering Manual,
for
details on provisioning the MSDT or DT Server.
Through the OSMINE process,
SLC
-2000 AIDs are supported in FACS and
OPS/INE. In addition,
TIRKS
OS and
NMA
OS organizations provide OSIA and
methods to inventory and assign
SLC
-2000 FITL facilities and equipment.
Table 8-14. Channel Unit Slot Restriction When Using an
SPQ
494 in a Three-Slot V-DT
Slot 1 can contain... Slot 2 can contain... Slot 3 can contain...
• SPQ
494
or
• AUA94
or
• Any other channel
unit supported by
the NBS
• SPQ
494
or
• AUA94
or
• Any other channel
unit supported by the
NBS
• AUA94
or
• Any other channel
unit supported by
the NBS (except the
SPQ
494 channel
unit)