363-206-305 System Turnup:
NTP-008
Issue 3, June 2000 Page 5 of 8
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
11.
NOTE:
Shelves that are part of a subnetwork being partitioned into
multiple sreas require that the NSAP
AREA
field and level 2
IS-IS routing parameters of the ent-ulsdcc-l3 command
be set. See Section 11 “Commands and Reports” in
363-206-285,
DDM-2000 OC-3 Multiplexer, TARP Release
13 and Later, User/Service Manual - Volume I
and this
manual, for an explanation of the command parameters and
824-102-144,
Lucent Technologies 2000 Product Family,
Operations Interworking Guide for TARP Releases
, for an
explanation of the engineering rules for subnetworking
partitioning.
Use the ent-ulsdcc-l3 command to designate the NSAP
AREA
field and level 2 IS-IS routing, as required.
DLP-535
12.
NOTE:
The rtrv-pm-line command in the following procedure
displays performance monitoring data associated with the
OC-1 lines terminated on the system.
Perform end-to-end OC-1 line test.
13. Repeat this procedure for all OC-1 optical spans being
established in the DDM-2000 OC-3/OC-1 network. Ensure that
the last optical span connected to the OC-3 host shelf is
connected to an OLIU in the opposite slot as the one in the first
OC-1 span (for example, slot 1 for the first span and slot 2(P) for
the second span).
14. The system is ready for initial service to be established.
Initial DS1 Service [System Turnup: NTP-004]
Initial T1 Service [System Turnup: NTP-013]
Initial HDSL Service [System Turnup: NTP-017]
Initial DS3 Service [System Turnup: NTP-025]
STS-3c Service [System Turnup: NTP-016]