363-206-305 System Turnup:
NTP-009
Issue 3, June 2000 Page 3 of 14
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
7.
NOTE:
OC-3 host shelves with Release 15 and FiberReach OC-1
hosted shelves with Release 4 software support AGNE(s)
and alarm groups. OC-3 host shelves with Release 13 and
FiberReach hosted shelves with Release 3 software do not
support these features and will not appear in the alarm
groups of a network with mixed software.
NOTE:
The Remote NE Status (rnestat) parameter of the
set-ne: command must be enabled prior to designating
the AGNE(s) and alarm group numbers.
NOTE:
FiberReach shelves may be designated as an alarm
gateway network element (AGNE) and assigned an alarm
group number. (Default alarm group number is 255.) At least
one AGNE is required per alarm group. One primary AGNE
and one backup per alarm group is recommmended. For a
network greater than 16 nodes, the AGNE and TL1 GNE
should be on separate nodes. The AGNE parameter of the
set-ne: command may have been set to yes on each new
shelf during shelf turnup procedures to suppress an AGNE
communication failure alarm.
Use the set-ne: command to designate the AGNE(s) and
alarm group numbers, as required.
8.
NOTE:
Multiple shelves are allowed in the dual-homed
configuration.