NTP-010
: System Turnup 363-206-305
Page 2 of 8 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
2. Verify that the host DDM-2000 OC-3 shelf is equipped with
Release 13 or 15 software. Verify that the hosted DDM-2000
FiberReach shelf is equipped with Release 3 or 4 software. If not
equipped with the proper software, upgrade with the proper
software.
3. Determine the optical loss of each optical span from office records
or by making the required measurements.
4.
NOTE:
The Network Side/User Side parameters of the
set-fecom: command must be set opposite at each end
of the optical spans. For example, see Figure 2.
Use the rtrv-fecom/set-fecom command to verify/set
"Network Side/User Side" parameters at each end of optical span
being established.
5.
NOTE:
The rtrv-sync: command retrieves the
Synchronization Report. This report displays the
provisioning and operational information on the
synchronization attributes of the DDM-2000. See the
"Commands and Reports" section of this manual for a
description of the rtrv-sync: command format.
Use the rtrv-sync: command to obtain the
Synchronization Report and verify if Sync
Autoreconfiguration is enabled. Use the set-sync: command to
enable the Sync Autoreconfiguration parameter, if required.
6. Verify no duplicate TID settings exist. The rtrv-ne: command
may be used at each shelf in the network to display settings. If
duplicates exist, determine new settings and use the set-ne:
command to make new settings.