EasyManua.ls Logo

Lucent Technologies FiberReach DDM-2000 - Page 1178

Lucent Technologies FiberReach DDM-2000
1896 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NTP-015
: Circuit Order 363-206-305
Page 2 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
3.
NOTE:
The following operation may activate the office major, minor,
or no alarm. The audible alarm may be suppressed by
depressing the
ACO
button.
NOTE:
One of the terminating nodes for the T1 service may be
equipped with
STS1E
circuit packs to provide an EC-1
interface for the DS1 service.
At the DS1 interconnect assembly, cross connect, or equivalent
sssembly at the T1 terminating nodes, remove the T1 signals
associated with the port(s) being discontinued. (
FAULT
LEDs
begin flashing on
T1EXT
circuit pack with signals removed.)
4.
NOTE:
The
UPD/INIT
pushbutton on the
SYSCTL
is recessed to
prevent its accidental operation. You will need a small
pointed object such as a ball-point pen to operate it.
Momentarily depress the
UPD/INIT
button on the
SYSCTL
at the
DS1 terminating nodes or use the upd command to update the
equipment list. (Flashing
FAULT
LEDs go off.)
5. Use the rtrv-state-eqpt: command to verify that the correct
port(s) has been changed from
in-service (i)
to
auto (a)
state.
6.
!
CAUTION:
Removing the wrong cross-connections may cause service
interruption.
From work order or rtrv-crs-( ) command, determine the
cross-connections for circuit being discontinued.

Table of Contents

Related product manuals