363-206-305 System Turnup:
NTP-020
Issue 3, June 2000 Page 9 of 14
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
19.
NOTE:
Shelves that are part of a subnetwork being partitioned into
multiple areas require that the NSAP
AREA
field and level 2
IS-IS routing parameters of the ent-ulsdcc-l3 command
be set. See Section 11 “Commands and Reports” in
363-206-295,
DDM-2000 OC-12 Multiplexer, TARP Release
7, User/Service Manual - Volume I
, 363-206-285,
DDM-2000
OC-3 Multiplexer, TARP Release 13 and Later, User/Service
Manual - Volume I
, and this manual, for an explanation of
the command parameters and 824-102-144,
Lucent
Technologies 2000 Product Family, Operations Interworking
Guide for TARP Releases
, for an explanation of the
engineering rules for subnetworking partitioning.
Use the ent-ulsdcc-l3 command to designate the NSAP
AREA
field and level 2 IS-IS routing, as required.
DLP-514
20. Perform optical fiber connections and verification of the integrity of
the optical span being established.
DLP-515
21.
NOTE:
The rtrv-pm-line: command in the following procedure
displays performance monitoring data associated with the
OC-3 lines terminated on the system.
Perform end-to-end OC-3 line test.
22. Repeat this procedure for all OC-3 optical spans being
established in the DDM-2000 OC-12/OC-3 network. Ensure that
the last optical span connected to the OC-12 host shelf is
connected to an OLIU in the opposite slot as the one in the first
OC-3 span (for example, slot 1 for the first span and slot 2(P) for
the second span).