NTP-021
: System Turnup 363-206-305
Page 4 of 12 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
10. Use the set-sync: command to provision the synchronization
mode switching, synchronization source, and output mode of
timing signals when the
28-Type
or
29-Type OLIU
s hardware is
provisioned to be line-timed. See the “Commands and
Reports”
section of this manual for a description of the set-sync:
command format.
11.
NOTE:
If Kbyte or Sbyte (sync messaging) is enabled for the
OC-3/OC-12 MAIN-1 and MAIN-2 optical interfaces on the
OC-3/OC-12 ring, it
must
be enabled at all nodes in the
FT-2000 ring.
NOTE:
The rtrv-oc3: or rtrv-oc12: command retrieves the
OC-3 Line Provisioning Report or OC-12 Line
Provisioning Report. This report displays the
provisioned configuration of OC-3/OC-12 lines. See the
"Commands and Reports" section of this manual for a
description of the rtrv-oc3: or rtrv-oc12: command
format.
Use the rtrv-oc3: or rtrv-oc12: command to obtain the
OC-3 Line Provisioning Report or OC-12 Line
Provisioning Report and verify if Kbyte/Sbyte is enabled.
Use the set-oc3: or set-oc12: command to enable the
Kbyte/Sbyte parameter, if required.