NTP-023
: System Turnup 363-206-305
Page 6 of 20 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED. . . . .FOR DETAILS, GO TO
13.
NOTE:
If Kbyte or Sbyte (sync messaging) is enabled for the
FiberReach OC-3
MAIN-1
and
MAIN-2
optical interfaces at
any node in the OC-3 ring, it
must
be enabled at all nodes in
the OC-3 ring and in the
FUNCTION UNITS
slots of the host
OC-12 shelf.
NOTE:
The rtrv-oc3: command retrieves the OC-3 Line
Provisioning Report. This report displays the
provisioned configuration of OC-3 lines. See the
"Commands and Reports" section of 363-206-295,
DDM-2000 OC-12 Multiplexer, TARP Release 7,
User/Service Manual - Volume I,
363-206-285,
DDM-2000
OC-3 Multiplexer, TARP Release 13 and Later, User/Service
Manual - Volume I,
and this manual, for a description of the
rtrv-oc3: command format.
Use the rtrv-oc3: command to obtain the OC-3 Line
Provisioning Report and verify if Kbyte/Sbyte is enabled.
Use the set-oc3: command to enable the Kbyte/Sbyte
parameter, if required.
14.
NOTE:
If Sync Autoreconfiguration is enabled, Kbyte/Sbyte must
also be enabled.
NOTE:
If Sync Autoreconfiguration is enabled at any line-timed
OC-3 node in a ring, it
must
be enabled at all line-timed
OC-3 nodes of a ring.