363-206-305 System Turnup:
NTP-023
Issue 3, June 2000 Page 11 of 20
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
DLP-51420. Perform optical fiber connections and verification of the integrity of
the optical span being established.
DLP-515
21.
NOTE:
The rtrv-pm-line command in the following procedure
displays performance monitoring data associated with the
OC-3 lines terminated on the system.
Perform end-to-end OC-3 line test.
22. Repeat this procedure for all OC-3 optical spans being
established in the DDM-2000 OC-12/OC-3 network. Ensure that
the last optical span connected to the OC-12 host shelf is
connected to an OLIU in the opposite slot as the one in the first
host OC-12 (for example in Figures 3 and 5, slot 1 at one host
node and slot 2(P) at the other host node).
23.
NOTE:
Establishing service requires that the proper slots in each
terminating node be properly equipped with the correct
circuit pack(s) for the type of service being established. It
also requires numerous cross connections in each of the
nodes representing the path of the required service.
Additionally, transmission tests should be performed to verify
the continuity and quality of the established circuit.
The dual-homed DDM-2000 OC-3 access network is now ready
for initial service to be established.
Initial DS1 Service [System Turnup: NTP-004]
Initial T1 Service [System Turnup: NTP-013]
Initial HDSL Service [System Turnup: NTP-017]
Initial DS3 Service [System Turnup: NTP-025]
STS-3c Service [System Turnup: NTP-016]