363-206-305 Trouble Clearing
:
Issue 3, June 2000 Page 1 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
TAP-101
Clear Critical (CR) Alarm
1. Connect the CIT to the
CIT
connector on the near-end User Panel and log in to
the near-end system, if not already performed.
Reference:
DLP-521
2.
NOTE:
The
rtrv-alm
command can be used to display a report of active alarm
and status conditions. The Commands and Reports section of this
manual gives a description of the command.
NOTE:
The
Active Alarm and Status Report
is output automatically
following CIT log in. The report shown in Figure 1 is an example that
shows several entries. There may be only one entry in the actual report.
Note the information in the
Source Address
and
Description
columns for
the top entry/entries above the first single- dashed line (for example,
"
CRITICAL ... inc. OC1 LOS
" in the report below) in the
Active Alarm
and Status Report.