TAP-101
: Trouble Clearing 363-206-305
Page 6 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
10. Replace
OLIU
s at far end that are associated with the Source Address of
the inc. OC1 line AIS, inc. OC3 line AIS, or inc. OC12 line
AIS alarm message.
Reference:
DLP-523
11.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
12. Issue a trouble report of a bad incoming DS3 signal from DSX-3 (STSX)
cross-connect point. Clear trouble using local procedures. If no trouble found,
replace
DS3
circuit pack at near end.
Reference:
DLP-523
13.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
14. Determine the reason the circuit packs were removed. If the same circuit pack
is to be reinserted and no switch settings are changed, reinstall the circuit
pack. If the circuit pack was removed and switch settings changed, reinstall
the circuit pack and momentarily depress the
UPD/INIT
button on the
SYSCTL
. If the circuit pack is not to be reinserted, momentarily depress the
UPD/INIT
button on the
SYSCTL
to remove the circuit pack from the inventory.
15.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.