363-206-305 Trouble Clearing:
TAP-102
Issue 3, June 2000 Page 3 of 14
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
MAJOR.
MJ
LED
lighted.
FAULT
LED
lighted on
circuit pack.
DS1 CP failed
DS1PM CP failed
T1EXT CP failed
Internal circuit pack failure. Step 41
SYSCTL CP failed Internal circuit pack failure. Step 29
MAJOR.
MJ
LED
lighted.
CP removed
DS1
,
DS1PM
, or
T1EXT
circuit
packs removed without doing update
(
upd
) command to remove circuit
packs from equipment list.
Step 39
unexpected CP
type
When associated with a low speed
slot, this message means that a
different but supported circuit pack
type (for example,
BBF3
) is inserted
in a slot already provisioned for
different circuit pack.
Step 47
unexpected CP
switches
When associated with the
SYSCTL
slot, this message means that an
invalid switch setting has been
selected on the circuit pack or that
some of the unused switches are not
in the prescribed position. For
DS1
,
DS1PM
, or
T1EXT
slots, this
message means that a change in a
circuit pack switch setting was made.
Step 50
inc. DS1 sync.
ref. LOS
inc. DS1 sync.
ref. LOF
inc. DS1 sync.
ref. BER
inc. DS1 sync.
ref. AIS
inc. DS1 sync.
ref. OOL
inc. DS1 sync.
ref. EOOF
Failure of
TGS/TG3
CP at far end, or
failure of upstream timing supply, or
timing eqpt.
Step 56
Table A – Major (MJ) Alarm Conditions (Continued)
Alarm Level
or LED
Indication
Trouble Description
(Note) Likely Causes Step or Procedure