363-206-305 Trouble Clearing
:
Issue 3, June 2000 Page 1 of 2
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
TAP-105
Clear Trouble Report
1. Is the CR alarm LED lighted on the User Panel?
If YES, do TAP-101.
If NO, continue with Step 2.
2. Is the MJ alarm LED lighted on the User Panel?
If YES, do TAP-102.
If NO, continue with Step 3.
3. Is the MN alarm LED lighted on the User Panel?
If YES, do TAP-112.
If NO, continue with Step 4.
4. Is the FAULT LED on the faceplate of a DS1, DS1PM, T1EXT, HDSL, or DS3
circuit pack flashing [inc. DS1 LOS or inc. DS3 LOS]?
If YES, continue with Step 5.
If NO, proceed to Step 7.
5. There appears to be an incoming DS1/DS3 signal failure. Refer to TAP-110
and clear the condition.
6. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
7. Is the FAULT LED on the faceplate of any circuit pack in the FiberReach
lighted (not flashing) [( ) CP failed]?
If YES, continue with Step 8.
If NO, proceed to Step 10.