TAP-106
: Trouble Clearing 363-206-305
Page 2 of 2 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
8.
!
CAUTION:
Replacing the
SYSCTL
involves updating the internal memory on the
circuit pack.
Refer to
DLP-501
and replace the
SYSCTL
.
9. Is the
FAULT
LED on the affected circuit pack still lighted?
If
YES
, continue with
Step 10
.
If
NO
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
10.
NOTE:
The problem appears to be in the backplane wiring of the FiberReach.
One way to verify this is to swap the
SYSCTL
and any circuit pack with an
inconsistent diagnostic indication with the corresponding circuit packs in
another FiberReach. If the problem moves with the circuit packs, it
means that one or more of the circuit packs is defective. If the problem
stays with the original FiberReach the entire assembly, but not the circuit
packs, should be replaced. The FiberReach has a printed backplane and
cannot be repaired in the field.
Check for bent or broken pins, shorted pins, etc. If you need technical
assistance, notify your supervisor, your local technical support organization, or
call Lucent Technologies RTAC, per local operating instructions.
11.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.