TAP-107
: Trouble Clearing 363-206-305
Page 2 of 22 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Figure 1 – Example of Active Alarms and Status Report
3.
NOTE:
Far-end alarm or status conditions are listed in this report with a Source
Address of farend. Local alarm or status conditions have a Source
Address of the local slot, line, port, channel, path, cross-connection, or
operations interface (DCC, TL1 (X.25), etc.) where the event occurred.
(See
Addresses
in the Commands and Reports section of this manual.)
Use the rtrv-alm: command to get another report, if necessary.
Does the Source Address of any top entry above the first single-dashed line
in the alarm report indicate a
local
alarm?
If
YES
, continue with
Step 4
.
If
NO
, proceed to
Step 6
.
/* Active Alarms and Status Report
=============================================================
Alarm Source Date Time Srv Description
Level Address Detected
=============================================================
MINOR farend MM-DD HH:MM:SS - SiteXNE1
MINOR farend MM-DD HH:MM:SS - SiteYNE1
-------------------------------------------------------------
ne-acty m1-1-1-1 MM-DD HH:MM:SS inc. VT AIS
*/