TAP-107
: Trouble Clearing 363-206-305
Page 4 of 22 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
NOTE:
If any systems have a Communications Status of FAILED, you may have
to log in to the system nearest to the system with a FAILED
communications status or issue a trouble report on the system you
cannot log into.
NOTE:
The far-end alarms refer to alarms in the same alarm group as the local
network element. For systems you cannot log into (FT-2000), issue a
trouble report on the system indicated in the Active Alarms and
Status Report.
If possible, enter the rlgn:tid command to log in to any far-end system
indicated in the top entry in the Active Alarms and Status Report (for
example,
MINOR farend MM-DD HH:MM:SS - SiteXNE1)
Reference:
DLP-522
8. Use the rtrv-alm: command at the far-end DDM-2000 system to get a
report of status and alarms. See Table B for a detailed description of the
messages in the Active Alarms and Status Report. For systems other
than DDM-2000 OC-3, FT-2000 OC-48, DDM-2000 FiberReach, DDM-2000
OC-12, and
SLC
®
-2000, etc., use the User/Service Manual for that system for
trouble clearing procedures.