TAP-109
: Trouble Clearing 363-206-305
Page 4 of 4 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
12. There is nothing more to be done until the reason for the
ABN
condition is
known.
13.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
14. Use the appropriate command to clear the abnormal condition. The command
will be rls-lpbk-( ) or
switch-( ).
15. Is the
ABN
indicator still lighted?
If
YES
, continue with
Step 16
.
If
NO
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
16. Use the rtrv-alm command to determine if there are other conditions
causing the
ABN
alarm. See Table A.
17. Does the rtrv-alm command report any other abnormal conditions. See
Table A.