EasyManua.ls Logo

Lucent Technologies FiberReach DDM-2000 - Page 1448

Lucent Technologies FiberReach DDM-2000
1896 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TAP-112
: Trouble Clearing 363-206-305
Page 8 of 16 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
MINOR.
MN
LED lighted.
inc. STS1 sig. degrade
(BER)
Failure of
OLIU
circuit
pack at some point in
the STS-1 path or failure
of receive fiber.
TAP-111
inc. STS1 sig. failed
(BER)
Failure of the near end
OLIU
circuit pack
reporting the STS-1
failure; failure of the far
end
OLIU
; or failure of
the receive fiber if the
OC-n is also reporting a
failure.
TAP-111
inc. STS1 unequipped An STS-1 cross-connect
has been deleted in
upstream equipment
interfacing with the
DDM-2000 OC-1, OC-3,
or OC-12 ring.
Find the deleted
cross-connect in the
upstream equipment.
inc. VT AIS* Incomplete or incorrect
cross-connect
provisioning in
end-to-end network;
unprotected removal or
failure of
DS1
,
DS1PM
,
or
T1EXT
circuit pack at
far end. In ring
applications; a
non-service affecting VT
AIS alarm message
may result from an
upstream
OLIU
circuit
pack or fiber failure
affecting only one ring
direction. A VT yellow
alarm message is not
returned for a
non-service affecting VT
AIS.
TAP-118
Table A – Minor (MN) Alarm Conditions (Continued)
Alarm Level or
LED Inidication Trouble Description (Note) Likely Causes Step or Procedure

Table of Contents

Related product manuals