363-206-305 Trouble Clearing:
TAP-118
Issue 3, June 2000 Page 3 of 4
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
13. Use the rlgn command, if possible, or have the central maintenance center
login to the other terminal shelf, then use the rtrv-crs-sts1: and
rtrv-crs-vt: commands to determine if the time slot identified in Step 12
is cross-connected as specified in circuit layout or other office records.
14. Were there incomplete or incorrect cross-connects?
If YES, continue with Step 15.
If NO, proceed to Step 17.
15. Use the commands ent-crs-( ) and dlt-crs-( ), as necessary. to
correct the provisioning.
16. Have all indications of VT AIS cleared?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, continue with Step 17.
17.
NOTE:
If the service is STS1 cross-connected at either terminating shelf, both
terminating shelves must be equipped to terminate the entire STS1.
Use the rtrv-state-eqpt: command at both shelves to verify that the
shelves are properly equipped for the service being provided. If the shelves
are not properly equipped, install circuit packs as required.
18. Have all indications of VT AIS cleared?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, continue with Step 19.
19. Use the rlgn command, if possible, or have the central maintenance center
login to a shelf where the service should be pass-through cross-connected (for
example, m-1-1-1 to c-1-1-1). Use the rtrv-crs-( ) command to determine
if the time slot identified in Step 12 is cross-connected as specified in circuit
layout or other office records. If service is cross-connected through other
maintenance subnetworks, such as dual ring interworking (DRI), look for
missing cross-connections in the other subnetworks.
20. Are there any missing cross-connects?
If YES, continue with Step 21.
If NO, proceed to Step 24.