363-206-305 Detailed Level Procedure:
DLP-504
Issue 3, June 2000 Page 3 of 4
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
6. Connect optical cables to MAIN-2 or FN-2 OLIU.
Response: MAIN-2 26-Type OLIU FAULT LED goes out.
MAIN-2 28-Type OLIU FAULT LED goes out.
MAIN-2 29-Type OLIU FAULT LED remains lit (solid).
FN-2 22-Type OLIU FAULT LED goes out.
7. Are 28/29-Type OLIUs being installed?
If YES, continue with Step 8.
If NO, proceed to Step 10.
8. Connect the faceplate connector (ribbon cable) between 28/29-Type OLIUs in
the MAIN-1 and MAIN-2 slots.
Response: 28-Type OLIU [MN LED (OLIU connector failed)
alarm will clear.]
29-Type OLIU FAULT LED goes out. MN LED (OLIU
connector failed and OLIU CP failed) alarm will
clear.
9. Verify that the connectors on the faceplate connector are properly seated and
latched.
10. Have all required OLIUs been installed?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
if NO, repeat this procedure for all OLIUs being installed.