DLP-505
: Detailed Level Procedure 363-206-305
Page 2 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
NOTE:
The lightguide jumpers used to loop the
OLIU
s must be equipped with
SC, FC, or
ST
connectors at both ends, depending on the type of
OLIU
connector. See Figures 1, 2, and 3.
NOTE:
The single-mode to single-mode (SM-SM) LBOs are installed on the
OUT
buildout block of the
OLIU
. The single-mode to multimode (SM-MM) or
multimode to multimode (MM-MM) LBOs are installed on the
IN
buildout
block of the
OLIU
.
Which
OLIU
s are being looped?
If
26G-U/26G2-U/29G-U/29H-U OLIU
, continue with
Step 2
.
If
22F-U/22F2-U/22G2-U/22G3-U/22G4-U/22D-U/28G-U/28G2-U
OLIU
s, proceed to
Step 7
.
2.
NOTE:
The
26G-U/26G2-U/29G-U/29H-U OLIU
s require single-mode lightguide
jumpers (Table A).
For the
26G-U/26G2-U OLIU
, replace the 0 dB LBO on the
OUT
or
IN
buildout
block(s) with the required 15 dB LBO on the
MAIN-1 OLIU
. For the
29G-U/29H-U OLIU
, replace the 0 dB LBO on the
OUT
or
IN
buildout block(s)
with the required 10 dB LBO on the
MAIN-1 OLIU
. See Tables B or C.
Table A – Single-Mode Lightguide Jumpers
Code Comcode Length (Feet) Connectors
FS1E-E-2 105357727 2 ST-ST
LS1SC-SC-2 106908247 2 SC-SC
LS1FP-FP-10 106593825 10 FC-FC
Table B Universal 10 dB Lightguide Buildouts
Code Comcode
Connector
Type
Cable
Connection Color
A3060D1 107406159 SC SM-SM Yellow
A3070D1 107406191 ST SM-SM Yellow
A3080D1 107406233 FC SM-SM Yellow
ASCS10 108314600 SC SM-SM Green
ASTS10 108053190
ST
SM-SM Green
AFCS10 108107194 FC SM-SM Green
ASCM10 108440595 SC SM-MM Beige
ASTM10 108052994 ST SM-MM Beige
AFCM10 108107301 FC SM-MM Beige