DLP-505
: Detailed Level Procedure 363-206-305
Page 6 of 6 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
9. Use lightguide jumpers to loop the
IN
and
OUT
connectors of the
MAIN-2
or
FN-2 OLIU
. See Tables A and E.
Response:
FAULT
LED stops flashing.
ACTIVE
LED remains on.
Major/Minor (
MJ/MN
) alarm goes off.
10.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.