DLP-506
: Detailed Level Procedure 363-206-305
Page 2 of 2 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
2. Set variable optical attenuator to obtain power level reading on optical power
meter as required from Table A.
3. Monitor the DS1 received signal with the DS1/DS3 Error Rate Test Set (ERTS)
for 30 minutes and ensure a bit error rate (BER) result of 10
–10
or better.
4. Did
OLIU
pass BER test?
If
YES
,
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
If
NO
, continue with
Step 5
.
5. Clean optical attenuators and connectors and repeat test. If test fails again,
replace
OLIU
.
Table A OC-1/OC-3/OC-12 OLIU Optical Power Levels
OC-1 OLIU Power Level (dBm)
26G-U, 26G2-U
–30.8
OC-3 OLIU Power Level (dBm)
22G-U
,
22G2-U
,
22G3-U
,
22G4-U
–34.0
22F-U
,
22F2-U
–34.0
22D-U
–33.8(Cont. Env.) –31.8(Uncont. Env.)
28G-U, 28G2-U
–34.0
OC-12 OLIU Power Level (dBm)
29G-U
–30.5
29H-U
–31.0