DLP-510
: Detailed Level Procedure 363-206-305
Page 8 of 8 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
43. Trouble may be in the DSX cross-connect or T1 interface wiring, VT1/STS1
cross-connections in the network, or the shelf backplane. Use the rtrv-crs-( )
command to ensure proper VT1/STS1 cross-connections have been made at
each shelf in the ring for the DS1 being tested. If no trouble found, check DSX
cross-connect, T1 interface wiring and backplane connections. If other alarms
or trouble indications are present, refer to
Trouble Clearing: IXL-001
to isolate
the trouble. If no alarms or indications are present and a CIT is available, use
the RETRIEVE commands (for example, rtrv-alm, rtrv-hsty, etc.) to
check for other trouble indications.
44.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.