DLP-513
: Detailed Level Procedure 363-206-305
Page 4 of 8 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Figure 2. DS1/DS1PM Option Settings
9.
NOTE:
It is recommended that a policy be established to set line coding either
using the option switches OR using the set-t1: command. If line code
(lc) parameters are set using the set-t1: command, the circuit pack
switch settings will have no effect. The rtrv-t1: command may be
used to check line code settings.
Refer to Table C and Figure 2 and set the line code option switches, if
required.
Note:
Switch 1, section 8 (
S1-8
) is unused and ignored by the system.
10.
STOP. YOU HAVE COMPLETED THIS PROCEDURE
.
Table C DS1/DS1PM Line Code Settings
Line Code
Format
Switch S1 Settings
S1-4
(Port 1)
S1-5
(Port 2)
S1-6
(Port 3)
S1-7
(Port 4)
S1-8
(Note)
B8ZS OFF OFF OFF OFF
OFF
AMI ONONONON