DLP-514
: Detailed Level Procedure 363-206-305
Page 10 of 22 Issue 3, June 2000
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
Table H – DDM-2000 FiberReach Operating at an OC-3 Rate to FT-2000 LS INTFC
Measured Optical Power and Required LBO
Notes
1. Measured power is defined to be the measured power of the light emitted from receive fiber con-
nector at OLIU.
2. The minimum measured received power allows for optical path penalty and unallocated margin.
Connector loss is not allotted for; it should already be accounted for in the optical power measure-
ment.
3. The margin for falling within the maximum rx power is 1.0 dB.
Receiver
LAA10 OC3
(FT-2000)
LAA5 OC3
(FT-2000) 28G-U/28G2-U OLIU
Transmitter
Received
Power (dBm)
LBO
(dB)
Received
Power (dBm)
LBO
(dB)
Received
Power (dBm)
LBO
(dB)
LAA10/LAA10B OC3
(FT-2000)
-7.0 to -34.0 0
LAA5 IS3
(FT-2000)
-14.0 to -15.0 5
-15.0 to -34.0 0
28G-U/28G2-U OLIU
0.0 to -5.0 15
0.0 to -3.0 10 -5.0 to -10.0 10
-3.0 to -8.0 5 -10.0 to -15.0 5
-8.0 to 34.0 0 -15.0 to -30.8 0